No. | Standard | Test Method | Result | ASTM Limits |
---|---|---|---|---|
According to the ASTM Standards, All the above test results exceeds the limits of ASTM Standards | ||||
1 | ASTM – C97 | Determination of Water Absorption | 1.4% | 3.0%(max.) |
2 | ASTM – C99-87 | Determination of Modules of Rupture | 1624 PSI | 1000 PSI(min.) |
3 | ASTM – C880-98 | Determination of Flexural Strength | 1406 PSI | 1000 PSI(min.) |
4 | ASTM – C170-90 | Determination of Compressive Strength | 11237 PSI | 8000 PSI(min.) |
5 | Determination of Density | 2575 (KG/M3) | 2560 (KG/M3)(min.) |